{"created":"2023-06-20T14:26:02.391216+00:00","id":1288,"links":{},"metadata":{"_buckets":{"deposit":"9e3fff23-9bd1-4dbd-925e-e073424abf96"},"_deposit":{"created_by":3,"id":"1288","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1288"},"status":"published"},"_oai":{"id":"oai:dmu.repo.nii.ac.jp:00001288","sets":["81:77"]},"author_link":["6390","6388","6387","6385","6391","6386","6389"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-03-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"4","bibliographicPageStart":"1","bibliographicVolumeNumber":"43","bibliographic_titles":[{"bibliographic_title":"Dokkyo journal of medical sciences"}]}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Background:Acceptance has grown for single-needle dialysis when a vascular access is not suited for the insertion of two needles. Its impact on flow patterns was unknown. Methods:We produced transparent life-size models of arteriovenous(AV)fistulas and AV grafts that we placed into a pulsatile flow system to examine flow characteristics during simulated dialysis cycles. For this purpose we injected dye, and recorded and analyzed the resulting flow patterns using suitable software tools. Results:There is a definite flow reversal during the arterial phases in both AV fistulas and -less pronounced-in AV grafts leading to flow oscillations. Conclusion:Flow oscillations initiate subintimal hyperplasia possibly leading to stenoses in vivo. Reversal of the flow direction may also cause steal phenomena in the poorly perfused distal extremity. Single-needle dialysis should therefore be avoided if possible.","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Original","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA00629581"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03855023","subitem_source_identifier_type":"ISSN"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"},{"subitem_text_language":"en","subitem_text_value":"Department Of Cardiac And Vascular Surgery, Dokkyo Medical University, Nikko Medical Center"},{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"},{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"},{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"},{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"},{"subitem_text_language":"en","subitem_text_value":"Department Of Vascular Surgery, Queen Elisabeth Hospital"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"Fluid Dynamics of Single-needle Dialysis in an Experimental Model"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Scholz, Hans","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsushita, Yasushi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Krueger, Ulf","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Wunsch, Matthias","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Lorenz, Uwe","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Petzold, Karen","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Zidane, Djamal","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-24"}],"displaytype":"detail","filename":"KJ00010141599.pdf","filesize":[{"value":"116.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00010141599.pdf","url":"https://dmu.repo.nii.ac.jp/record/1288/files/KJ00010141599.pdf"},"version_id":"856e76ed-c9b4-4cb6-9e88-d90280310ffe"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Hemodynamic Patterns","subitem_subject_language":"en"},{"subitem_subject":"Single-needle Dialysis","subitem_subject_language":"en"},{"subitem_subject":"Vascular Access","subitem_subject_language":"en"},{"subitem_subject":"Intimal Hyperplasia","subitem_subject_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Fluid Dynamics of Single-needle Dialysis in an Experimental Model","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Fluid Dynamics of Single-needle Dialysis in an Experimental Model","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["77"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-24"},"publish_date":"2017-05-24","publish_status":"0","recid":"1288","relation_version_is_last":true,"title":["Fluid Dynamics of Single-needle Dialysis in an Experimental Model"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T16:02:21.008422+00:00"}