{"created":"2023-06-20T14:26:27.606805+00:00","id":1990,"links":{},"metadata":{"_buckets":{"deposit":"278c3011-137c-4187-947c-b8ee68d59304"},"_deposit":{"created_by":14,"id":"1990","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"1990"},"status":"published"},"_oai":{"id":"oai:dmu.repo.nii.ac.jp:00001990","sets":["159:164"]},"author_link":["9260","9259","9258","9255","9256","9257"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-05-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"28","bibliographicPageStart":"19","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"獨協医科大学看護学部紀要"},{"bibliographic_title":"Bulletin of Dokkyo Medical University School of Nursing","bibliographic_titleLang":"en"}]}]},"item_10002_description_24":{"attribute_name":"要旨","attribute_value_mlt":[{"subitem_description":" 本研究は,在宅用に開発された消臭機を病室内の臭気対策に応用し,その性能評価を実施するとともに,おむつ交換の手技を統一することで,おむつ交換時に発生する臭気の拡散を抑え,病室全体の臭気のレベルが改善可能かどうか明らかにすることを目的とした.\n 病室内に消臭機を設置する前の臭気強度は1 ~ 2であり,何らかの臭気の存在を感じていたが,消臭機の設置により,臭気強度は1 未満となり,病室内全体はほぼ無臭に近い状態となった.一般住宅の在宅療養用に開発された消臭機であったが,4床室程度の病室には2台の設置により消臭効果が認められた.\n 7分の時間を要した従来のおむつ交換方法は,排泄物の空気中への曝露時間が長くなり,病室全体の臭気のレベルが上昇したが,統一した手技によるおむつ交換では,所要時間が2分に短縮され,おむつ交換直後の臭気強度は3.0,その後は1.5未満まで低下し,臭気のレベルが低減された.おむつ交換時間の短縮と排泄物の空気中への曝露時間を抑えることで適切な臭気の発生源管理ができ,病室全体の臭気のレベルを改善することが可能となった.","subitem_description_type":"Other"}]},"item_10002_description_25":{"attribute_name":"要旨(英)","attribute_value_mlt":[{"subitem_description":"In this study, the performance evaluation was conducted on whether the deodorizer manufactured for home can be applied to mitigate of patient room odor. Moreover, it demonstrated whether or not unifying adult diaper exchange procedure prevents dispersion of odor and improve the level of odor in patient room. The odor intensity before installing a deodorizer in patient room was 1 ~ 2 and it was thought that it indicates the presence of some odor. However, the odor intensity became less than 1 by installing a deodorizer and the condition inside the patient room changed into almost odorless. For a capacious patient room about the size of 4-bed room, the deodorization efficiency was recognized by installing two deodorizers for home. Since the exposure time of excrement in the air was long when the traditional method of adult diaper exchange in 7 minutes, the level of patient room odor rose. However, using the unified procedure of adult diaper exchange cut the required time to 2 minutes. Furthermore, the odor intensity immediately after adult diaper exchange was 3.0 and it fell to less than 1.5 after that, thus the odor level went down. It became possible to improve the level of patient room odor by shortening the time of adult diaper exchange and excrement exposure in the air.","subitem_description_type":"Other"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"獨協医科大学看護学部"}]},"item_10002_relation_12":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"40018856904","subitem_relation_type_select":"NAID"}}]},"item_10002_relation_26":{"attribute_name":"医中誌ID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2011235627","subitem_relation_type_select":"ICHUSHI"}}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00629581","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18830005","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"板倉, 朋世"}],"nameIdentifiers":[{"nameIdentifier":"9255","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鯉沼, とも子"}],"nameIdentifiers":[{"nameIdentifier":"9256","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長山, 忠司"}],"nameIdentifiers":[{"nameIdentifier":"9257","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tomoyo, Itakura","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"9258","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tomoko, Koinuma","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"9259","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Cyuuji, Nagayama","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"9260","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-12-21"}],"displaytype":"detail","filename":"BDMUSN-5-1-4.pdf","filesize":[{"value":"991.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"BDMUSN-5-1-板倉-本文","url":"https://dmu.repo.nii.ac.jp/record/1990/files/BDMUSN-5-1-4.pdf"},"version_id":"86098bda-44b6-4b22-8b34-8f5c30eb878d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"病室","subitem_subject_scheme":"Other"},{"subitem_subject":"おむつ交換","subitem_subject_scheme":"Other"},{"subitem_subject":"排泄物臭","subitem_subject_scheme":"Other"},{"subitem_subject":"消臭","subitem_subject_scheme":"Other"},{"subitem_subject":"Patient room","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Adult diaper exchange","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Odors from excrement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Deodorization","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"おむつ交換時における病室内の臭気のレベルに関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"おむつ交換時における病室内の臭気のレベルに関する研究"},{"subitem_title":"Research on the Level of Odor in a Patient Room at the Adult Diaper Exchange","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"14","path":["164"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-10"},"publish_date":"2019-01-10","publish_status":"0","recid":"1990","relation_version_is_last":true,"title":["おむつ交換時における病室内の臭気のレベルに関する研究"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2023-06-20T15:38:56.812112+00:00"}