{"created":"2024-02-01T05:08:15.018837+00:00","id":2000104,"links":{},"metadata":{"_buckets":{"deposit":"f4b8ff20-9747-4393-92f7-87fa15a1d428"},"_deposit":{"created_by":14,"id":"2000104","owner":"14","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"2000104"},"status":"published"},"_oai":{"id":"oai:dmu.repo.nii.ac.jp:02000104","sets":["81:1706758513382"]},"author_link":[],"control_number":"2000104","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-12-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"131","bibliographicPageStart":"123","bibliographicVolumeNumber":"50","bibliographic_titles":[{"bibliographic_title":"Dokkyo Journal of Medical Sciences"}]}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"バセドウ病の RI 内用療法では甲状腺重量の推定が必要である.甲状腺重量の測定方法として,従来から甲状腺シンチグラフィを用いた Allen-Goodwin 法,大久保法,Himanka 法など 3 つの方法が知られている.我々は,これら 3 つの方法に加えて,甲状腺の側面撮像を行い,楕円体の体積を求める公式に代入した式(楕円法)を入れた 4 つの方法で既知のシリンジ体積を対象として,甲状腺の推定重量の至適 cut off 値を求めた.また甲状腺 SPECT/CT 法で求めた甲状腺の推定重量との比較検討を行った.\n 解析の結果,Himanka 法での至適 cut off 値は,Allen-Goodwin 法および大久保法よりも変動が少なかった.また楕円法による至適 cut off 値は,5 mL を除き,30% となり一定であった.甲状腺シンチグラフィによる重量推定では,至適 cut off 値を選定できれば,CT による被ばくを患者に与えること無く SPECT/CT 法と同様に甲状腺の重量を推定することが可能である.","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"In radioiodine therapy for Graves’ disease, it is necessary to estimate the thyroid weight. Four methods, including the Allen-Goodwin, Ohkubo, and Himanka methods, which use thyroid scintigraphy, and a method that involves taking a lateral view of the thyroid and using an equation that substitutes the elliptical body’s volume (elliptical method),were used to determine the optimal cut-off value for estimating the known syringe volume as the estimated weight. A comparison was made between the estimated weight obtained using SPECT/CT and that obtained using each methods. As a result, the optimal cutoff value in the Himanka method had less variation than the Allen-Goodwin and Ohkubo methods. The optimal cut-off value in the elliptical method was constant at 30 % except for 5 ml. If an appropriate cut-off value is selected for estimating weight based on thyroid scintigraphy, weight estimation can be performed similarly to SPECT/CT and additional radiation exposure from CT.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"獨協医学会"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00629581","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-5023","subitem_source_identifier_type":"PISSN"}]},"item_10001_text_33":{"attribute_name":"記事種別","attribute_value_mlt":[{"subitem_text_value":"原著"}]},"item_10001_version_type_20":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"長野, 圭司","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"高井, 剛","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"花岡, 宏平","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"奥畑, 勝也","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"久保, 誠","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"板垣, 康","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"清水, 栄美","creatorNameLang":"ja"}]},{"creatorNames":[{"creatorName":"中神, 佳宏","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-02-01"}],"filename":"DJMS-50-2-8.pdf","filesize":[{"value":"588 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"url":"https://dmu.repo.nii.ac.jp/record/2000104/files/DJMS-50-2-8.pdf"},"version_id":"b85c992a-12b2-4ed6-bd28-095c9a49ce96"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"バセドウ病","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"甲状腺シンチグラフィ","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"甲状腺重量推定","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"至適 cut off 値","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"SPECT/CT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Graves’ disease","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Thyroid scintigraphy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Thyroid weight estimation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Suitable cut-off value","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Single photon emission computed tomography/Computed tomography","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"甲状腺シンチグラフィによる甲状腺重量推定方法の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"甲状腺シンチグラフィによる甲状腺重量推定方法の検討","subitem_title_language":"ja"},{"subitem_title":"Consideration of Thyroid Weight Estimation Methods Using Thyroid Scintigraphy","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"14","path":["1706758513382"],"publish_date":"2024-02-01","publish_status":"0","recid":"2000104","relation_version_is_last":true,"title":["甲状腺シンチグラフィによる甲状腺重量推定方法の検討"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-04-22T07:29:30.042931+00:00"}