{"created":"2023-06-20T14:25:35.970123+00:00","id":771,"links":{},"metadata":{"_buckets":{"deposit":"ba8b9ac6-a15c-48b5-a999-bd36230b4f2d"},"_deposit":{"created_by":3,"id":"771","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"771"},"status":"published"},"_oai":{"id":"oai:dmu.repo.nii.ac.jp:00000771","sets":["81:50"]},"author_link":["3198","3194","3195","3201","3196","3197","3200","3199"],"item_2_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-07-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"88","bibliographicPageStart":"83","bibliographicVolumeNumber":"36","bibliographic_titles":[{"bibliographic_title":"Dokkyo journal of medical sciences"}]}]},"item_2_description_10":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"目的 水素クリアランス法による眼内組織の血流量の再現性を評価する.方法 家兎を用いて毛様体,脈絡膜,網膜の血流量を水素クリアランス法により3回繰り返し測定し,再現性の指標であるk 係数( Intraclass Correlation Coefficient) を求めた.結果 毛様体の血流量は1回目167.8± 70.0 ml/min/100 g,2回目170.5±69.6,3回目171.8±70.2であり,そのk の平均が0.874であった.脈絡膜の血流量は1回目212.2±78.8,2回目213.7±79.5,3回目216.4±80.5であり,k の平均が0.888であった.網膜の血流量は1回目165.6±70.1,2回目165.3±68.9.,3回目165.5±68.4であり,k の平均が0.988であった.結論 家兎眼の眼内組織の血流量測定において水素クリアランス法は再現性に優れた方法であることが確認された.","subitem_description_type":"Other"}]},"item_2_description_11":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"We measured ciliary body, choroidal and retinal bloodflow( CiBF,CBF,RBF) using hydrogen clearance method inalbino rabbits in repeated measurement for three times. Weconsidered k(Intraclass Correlation Coefficient)which wasan index for reproducibility of the ocular blood flow measurement.CiBF was 167.8±70.0 ml/min/100 g at first , 170.5±69.6at second, 171.8 ± 70.2 at third and the average of k was0.874. CBF was 212.2 ± 78.8 at first, 213.7 ± 79.5 at second,216.4 ± 80.5 at third and the average of k was 0.888. RBFwas 165.6 ± 70.1 at first, 165.3 ± 68.9 at second, 165.5 ± 68.4at third and the average of k was 0.988.This results confirmed that the hydrogen clearance methodhad a high reproducibility and an excellent method.","subitem_description_type":"Other"}]},"item_2_description_8":{"attribute_name":"記事種別(日)","attribute_value_mlt":[{"subitem_description":"原著","subitem_description_type":"Other"}]},"item_2_description_9":{"attribute_name":"記事種別(英)","attribute_value_mlt":[{"subitem_description":"Original","subitem_description_type":"Other"}]},"item_2_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA00629581"}]},"item_2_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03855023","subitem_source_identifier_type":"ISSN"}]},"item_2_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"獨協医科大学越谷病院眼科"},{"subitem_text_value":"サトウ眼科クリニック"},{"subitem_text_value":"獨協医科大学越谷病院眼科"},{"subitem_text_value":"獨協医科大学越谷病院眼科"}]},"item_2_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Dokkyo Medical University Koshigaya Hospital"},{"subitem_text_language":"en","subitem_text_value":"Sato Eye Clinic"},{"subitem_text_language":"en","subitem_text_value":"Dokkyo Medical University Koshigaya Hospital"},{"subitem_text_language":"en","subitem_text_value":"Dokkyo Medical University Koshigaya Hospital"}]},"item_2_title_3":{"attribute_name":"論文名よみ","attribute_value_mlt":[{"subitem_title":"カト ガンモウ ヨウタイ, ミャクラク マク, モウマク ケツリュウ リョウ ソクテイ ニオケル スイソ クリアランス ホウ ノ サイゲン セイ"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"武藤, 哲也"},{"creatorName":"ムトウ, テツヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 剛"},{"creatorName":"サトウ, ツヨシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松本, 行弘"},{"creatorName":"マツモト, ユキヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"筑田, 眞"},{"creatorName":"チクダ, マコト","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mutoh, Tetsuya","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Satoh, Tsuyoshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsumoto, Yukihiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Chikuda, Makoto","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-24"}],"displaytype":"detail","filename":"KJ00006360499.pdf","filesize":[{"value":"372.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KJ00006360499.pdf","url":"https://dmu.repo.nii.ac.jp/record/771/files/KJ00006360499.pdf"},"version_id":"778c06fb-5104-4f3a-ac26-7603c41ead36"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"水素クリアランス法"},{"subitem_subject":"眼内血流量測定"},{"subitem_subject":"再現性"},{"subitem_subject":"hydrogen clearance method","subitem_subject_language":"en"},{"subitem_subject":"ocular blood flow","subitem_subject_language":"en"},{"subitem_subject":"reproducibility","subitem_subject_language":"en"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"家兎眼毛様体,脈絡膜,網膜血流量測定における水素クリアランス法の再現性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"家兎眼毛様体,脈絡膜,網膜血流量測定における水素クリアランス法の再現性"},{"subitem_title":"Reproducibility of Intraocular Blood Flow Measurement in Rabbit Eyes Using Hydrogen Clearance Method","subitem_title_language":"en"}]},"item_type_id":"2","owner":"3","path":["50"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-24"},"publish_date":"2017-05-24","publish_status":"0","recid":"771","relation_version_is_last":true,"title":["家兎眼毛様体,脈絡膜,網膜血流量測定における水素クリアランス法の再現性"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-06-20T16:16:33.698334+00:00"}