  1. Dokkyo Medical Journal
  2. 2(4) 2023

Differences in Intraocular Lens Surface Properties and Lens Epithelial Cell Behavior

https://dmu.repo.nii.ac.jp/records/2000178
https://dmu.repo.nii.ac.jp/records/2000178
da271427-51f2-4755-a25d-1ae123428bac
名前 / ファイル ライセンス アクション
DKMJ-2-4-5.pdf DKMJ-2-4-5.pdf (541 KB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
タイトル
タイトル Differences in Intraocular Lens Surface Properties and Lens Epithelial Cell Behavior
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 cell behavior
キーワード
言語 en
主題Scheme Other
主題 cell culture
キーワード
言語 en
主題Scheme Other
主題 lens epithelial cells
キーワード
言語 en
主題Scheme Other
主題 secondary cataract
キーワード
言語 en
主題Scheme Other
主題 secondary cataract
キーワード
言語 en
主題Scheme Other
主題 surface modification
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Okayasu, Akihiko

× Okayasu, Akihiko

en Okayasu, Akihiko

Search repository
Mukai, Koichiro

× Mukai, Koichiro

en Mukai, Koichiro

Search repository
Matsushima, Hiroyuki

× Matsushima, Hiroyuki

en Matsushima, Hiroyuki

Search repository
Nagata, Mayumi

× Nagata, Mayumi

en Nagata, Mayumi

Search repository
Senoo, Tadashi

× Senoo, Tadashi

en Senoo, Tadashi

Search repository
書誌情報 en : Dokkyo Medical Journal

巻 2, 号 4, p. 289-294, 発行日 2023-12-25
記事種別
値 Original
内容記述
内容記述タイプ Abstract
内容記述 Posterior capsule opacification is a common complication following cataract surgery. However, its incidence varies depending on the type of intraocular lens (IOL) used. In this study, we analyzed the adhesion and movement of lens epithelial cells (LECs) in the early stages after cataract surgery by continuously observing LECs seeded on the surfaces of different types of IOLs. PY-60AD and XY1 hydrophobic acrylic IOLs were used. Each posterior surface was modified to increase the adhesion. The IOLs were placed in culture dishes with an exposed posterior or anterior surface (three each). LECs extracted from white rabbit lenses by trypsinization were seeded onto IOLs. LEC movement and shape were recorded by microscopy using a cell culture observation system after 6 h of contact between LECs and IOLs. The cumulative distance traveled was calculated from the LEC trajectories after comparing the shapes of the LECs. We observed that LECs were more likely to adhere to XY1 modified posterior surface. The speed of LEC movement decreased after adhesion. These findings support the conclusion that increasing the adhesiveness of IOL surfaces inhibits the LEC movement.
言語 en
出版者
出版者 Dokkyo Medical Society
ISSN
収録物識別子タイプ EISSN
収録物識別子 2436-522X
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA12941861
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.51040/dkmj.2023-010
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2024-02-09 02:25:24.079499
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3