WEKO3
アイテム
{"_buckets": {"deposit": "796fdfb2-d74f-4d82-b2af-1dc5b9e4695a"}, "_deposit": {"created_by": 3, "id": "758", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "758"}, "status": "published"}, "_oai": {"id": "oai:dmu.repo.nii.ac.jp:00000758", "sets": ["49"]}, "author_link": ["3182"], "item_2_biblio_info_12": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-03-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "T7", "bibliographicPageStart": "T1", "bibliographicVolumeNumber": "36", "bibliographic_titles": [{"bibliographic_title": "Dokkyo journal of medical sciences"}]}]}, "item_2_description_10": {"attribute_name": "抄録(日)", "attribute_value_mlt": [{"subitem_description": "QT 間隔のばらつき (QTD) の増加は,不整脈の発生や循環系合併症のリスクを上昇させる.本研究では,気管挿管に伴うQT 間隔,rate-corrected QT(QTc間隔),QTD,rate-corrected QTD(QTcD)の変動に対するb 受容体遮断薬であるランジオロールの予防効果について検討した.全身麻酔下に耳鼻咽喉科手術が予定された米国麻酔学会分類Iの患者30名(男性15名,女性15名)を対象とし,L群(麻酔導入前よりランジオロールを0.125 mg/kgの初回投与に引き続いて,0.04 mg/kg/分で持続投与した群),P 群(同量の生理食塩水を持続投与した群)に分けて,比較検討した.麻酔の導入はプロポフォール,セボフルランにより行い,ランジオロールもしくは生理食塩水の投与6分後に気管挿管した.平均動脈圧の変動は両群間に差はなかったが,麻酔導入後や気管挿管後に観察されたQT 間隔,QTc 間隔,QTD,QTcDの上昇はP 群と比較して有意にL 群で低値を示した.本研究の結果から,ランジオロールの投与が,麻酔中や気管挿管後の不整脈の発生や循環系合併症の予防に有用である可能性が示唆された", "subitem_description_type": "Other"}]}, "item_2_description_15": {"attribute_name": "表示順", "attribute_value_mlt": [{"subitem_description": "12", "subitem_description_type": "Other"}]}, "item_2_description_16": {"attribute_name": "アクセション番号", "attribute_value_mlt": [{"subitem_description": "KJ00006354219", "subitem_description_type": "Other"}]}, "item_2_description_8": {"attribute_name": "記事種別(日)", "attribute_value_mlt": [{"subitem_description": "学位申請論文", "subitem_description_type": "Other"}]}, "item_2_source_id_1": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00629581", "subitem_source_identifier_type": "NCID"}]}, "item_2_source_id_19": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03855023", "subitem_source_identifier_type": "ISSN"}]}, "item_2_text_6": {"attribute_name": "著者所属(日)", "attribute_value_mlt": [{"subitem_text_value": "獨協医科大学麻酔科学"}]}, "item_2_title_3": {"attribute_name": "論文名よみ", "attribute_value_mlt": [{"subitem_title": "キカン ソウカン ニ トモナウ QT カンカク オヨビ QT dispersion ノ ヘンドウ ニ タイスル ランジオロール ノ ヨボウ コウカ ニ ツイテ"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "金子, 瑞恵"}, {"creatorName": "カネコ, ミズエ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "3182", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-05-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00006354219.pdf", "filesize": [{"value": "423.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 423600.0, "url": {"label": "KJ00006354219.pdf", "url": "https://dmu.repo.nii.ac.jp/record/758/files/KJ00006354219.pdf"}, "version_id": "89442b4e-978d-4230-8c04-0920419e17d7"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "QT 間隔", "subitem_subject_scheme": "Other"}, {"subitem_subject": "QT dispersion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ランジオロール", "subitem_subject_scheme": "Other"}, {"subitem_subject": "気管挿管", "subitem_subject_scheme": "Other"}, {"subitem_subject": "不整脈", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "気管挿管に伴うQT 間隔およびQT dispersionの変動に対するランジオロールの予防効果について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "気管挿管に伴うQT 間隔およびQT dispersionの変動に対するランジオロールの予防効果について"}]}, "item_type_id": "2", "owner": "3", "path": ["49"], "permalink_uri": "https://dmu.repo.nii.ac.jp/records/758", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-05-24"}, "publish_date": "2017-05-24", "publish_status": "0", "recid": "758", "relation": {}, "relation_version_is_last": true, "title": ["気管挿管に伴うQT 間隔およびQT dispersionの変動に対するランジオロールの予防効果について"], "weko_shared_id": 3}
気管挿管に伴うQT 間隔およびQT dispersionの変動に対するランジオロールの予防効果について
https://dmu.repo.nii.ac.jp/records/758
https://dmu.repo.nii.ac.jp/records/758140dd7a0-353a-4805-9d83-221a5fabac53
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | [ELS]学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-05-24 | |||||
タイトル | ||||||
タイトル | 気管挿管に伴うQT 間隔およびQT dispersionの変動に対するランジオロールの予防効果について | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | QT 間隔 | |||||
キーワード | ||||||
主題 | QT dispersion | |||||
キーワード | ||||||
主題 | ランジオロール | |||||
キーワード | ||||||
主題 | 気管挿管 | |||||
キーワード | ||||||
主題 | 不整脈 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
雑誌書誌ID | ||||||
収録物識別子 | AA00629581 | |||||
論文名よみ | ||||||
タイトル | キカン ソウカン ニ トモナウ QT カンカク オヨビ QT dispersion ノ ヘンドウ ニ タイスル ランジオロール ノ ヨボウ コウカ ニ ツイテ | |||||
著者 |
金子, 瑞恵
× 金子, 瑞恵 |
|||||
著者所属(日) | ||||||
獨協医科大学麻酔科学 | ||||||
記事種別(日) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 学位申請論文 | |||||
抄録(日) | ||||||
内容記述タイプ | Other | |||||
内容記述 | QT 間隔のばらつき (QTD) の増加は,不整脈の発生や循環系合併症のリスクを上昇させる.本研究では,気管挿管に伴うQT 間隔,rate-corrected QT(QTc間隔),QTD,rate-corrected QTD(QTcD)の変動に対するb 受容体遮断薬であるランジオロールの予防効果について検討した.全身麻酔下に耳鼻咽喉科手術が予定された米国麻酔学会分類Iの患者30名(男性15名,女性15名)を対象とし,L群(麻酔導入前よりランジオロールを0.125 mg/kgの初回投与に引き続いて,0.04 mg/kg/分で持続投与した群),P 群(同量の生理食塩水を持続投与した群)に分けて,比較検討した.麻酔の導入はプロポフォール,セボフルランにより行い,ランジオロールもしくは生理食塩水の投与6分後に気管挿管した.平均動脈圧の変動は両群間に差はなかったが,麻酔導入後や気管挿管後に観察されたQT 間隔,QTc 間隔,QTD,QTcDの上昇はP 群と比較して有意にL 群で低値を示した.本研究の結果から,ランジオロールの投与が,麻酔中や気管挿管後の不整脈の発生や循環系合併症の予防に有用である可能性が示唆された | |||||
書誌情報 |
Dokkyo journal of medical sciences 巻 36, 号 1, p. T1-T7, 発行日 2009-03-25 |
|||||
ISSN | ||||||
収録物識別子 | 03855023 |