Item type |
[ELS]学術雑誌論文 / Journal Article(1) |
公開日 |
2017-05-24 |
タイトル |
|
|
タイトル |
Hemolytic Anemia soon after Replacement of Ascending Aorta for acute Aortic Dissection |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
言語 |
en |
|
主題 |
Replacement Of Ascending Aorta |
キーワード |
|
|
言語 |
en |
|
主題 |
Hemolytic Anemia |
キーワード |
|
|
言語 |
en |
|
主題 |
Teflon Felt Strip |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
雑誌書誌ID |
|
|
収録物識別子 |
AA00629581 |
論文名よみ |
|
|
タイトル |
Hemolytic Anemia soon after Replacement of Ascending Aorta for acute Aortic Dissection |
著者 |
Shibasaki, Ikuko
Fukuda, Hirotsugu
Yamada, Yasuyuki
Kuwata, Toshiyuki
Ogawa, Hironaga
Tsuchiya, Go
Hori, Takayuki
Takei, Yusuke
Kato, Takashi
|
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
著者所属(英) |
|
|
|
en |
|
|
Department Of Cardiac And Vascular Surgery, Dokkyo Medical University School Of Medicine |
記事種別(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Case Report |
抄録(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
A 61-year-old female underwent replacement of the ascending aorta for Type A aortic dissection, then gradually developed severe hemolytic anemia over 1 month. The cause of hemolysis was found to be mechanical damage of red blood cells caused by an inverted felt strip at the proximal anastomosis. A reoperation for resection of the felt and repair of the proximal anastomosis successfully resolved the problem. Here, we report a rare case of hemolytic anemia at the site of an inverted felt strip that occurred after replacement of the ascending aorta. |
書誌情報 |
Dokkyo journal of medical sciences
巻 42,
号 1,
p. 37-41,
発行日 2015-03-25
|